CD03 value corresponds to the
time of deceleration from 50/60HZ
to 0.
F
60HZ
0.1
6000 TIME(Sec)
Use terminal control refer to CD12
and CD42 setting,
keyboard control refer to CD06.
Time(Sec)
Jog command
Time(Sec)
1200HZ
0HZ
When setting this value, pay
attention to the starting current.
Time(Sec)
Run command
Time(Sec)
Fset
30HZ
0.5HZ
Deceleration time 1
CD03
Jogging frequency
CD04
Start frequency
CD05
34
Setting Range 0.1 ~ 6000.0Sec
Default value 10.0Sec
Setting Range 0.0 ~ 1200HZ
Default value 5.0HZ
Setting Range 0.5 ~ 30.0HZ
Default value 0.5HZ