Loading...
0 : Operation frequency change by using or key and
confirm by .
1 : Operation frequency depends on the analog signal.
Note : Using key to change motor speed when
CD01=1, the
OPE3 warning message will be indicated.
Dynamic brake /
Free running
CD11
0 : Activates dynamic brake
function when deceleration.
1 : Output cut off when accept
a stop command to be free
running.
0 : RUN/STOP Command from operation panel.
1 : RUN/STOP Command from control terminal.
Note : If inadequate operation, the OPE4 warning message will be
indicated.
CD11=1
CD11=0
FWD RUN
Command
time
time
time
F
F
PROG
36
Setting Range 0 or 1
60HZ region 0
50HZ region 1
Setting Range 0 or 1
Default value 1
Setting Range 0 or 1
Default value 0
Analog / Digital
frequency input
CD10
Terminal / Keypad
command
CD12