ADTECH9 Series CNC Programming Manual
Local Coordinate System Diagram
Format:
G52 X_Y_Z_;
XY_Z_; Equivalent to the offset of current G54~G59 coordinate
systems,
Details:
In this instruction, IP_specifies the offset equivalent to current G54~G59 coordinate systems, i.e. IP_specifies
the position coordinates of local coordinate system origin in current G54~G59 coordinate system.
G52 instruction is always valid after specified until next G52 instruction is specified.
G52 instruction can set the processing coordinate system without changing the workpiece coordinate system.
G52 IP0 (G52 X0 Y0 Z 0 α0) can be used to cancel local coordinate system.
The setting of local coordinate system doesn’t change the machine tool coordinate and workpiece coordinate
system.
G52 instruction can replace G92 instruction to specify the offset between the origin of processing program and
workpiece origin.
Example:
Local coordinate system in absolute value mode
G28 X0 Y0;
G00 G90 X1000 Y1000;
G92 X0 Y0; define workpiece coordinate system
G00 X500 Y500;

Table of Contents

Other manuals for Adtech CNC9640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech CNC9640 and is the answer not in the manual?

Adtech CNC9640 Specifications

General IconGeneral
BrandAdtech
ModelCNC9640
CategoryControl Systems
LanguageEnglish

Related product manuals