EKI-1221/1222/1224 User Manual 6
2.1 Understanding EKI-1221/1222/1224
Networks have become increasingly vital for industrial automation applications. Many
control devices today do not have a network port and can only communicate with a
dedicated local PC or control panel. Advantech’s revolutionary network-enabling
technology is now allowing control devices with serial ports to connect to the Ethernet
and share networks quickly and cost-effectively. The EKI-1221/1222/1224 is
network-based, Modbus data gateway for integrating new and existing Modbus/RTU
and Modbus/ASCII serial devices to newer TCP/IP networked-based devices.
Manufacturers, system integrators, and end users can now take advantage of the
EKI-1221/1222/1224 to create networked applications for remote managing and
accessing data for their control devices that wasn’t possible before.
2.1.1 Protocol Overview
Originally developed for PLCs in industrial automation and manufacturing control
application, Modbus has become one of the most popular open standard protocols in
use today. When it comes to planning data communication for open, multi-vendor
industrial control systems, Modbus is the first choice of end-users and integrators.
Although it’s not the most powerful protocol available, its rare simplicity allows not
only rapid implementation, but also remains flexible enough to be applied in virtually
all industrial situations. The communication mode of Modbus can be ASCII, RTU, or
TCP/IP. The EKI-1221/1222/1224 is used to support applications such as protocol
conversion between serial (Modbus/ASCII or Modbus/RTU) and networked (Modbus/
TCP) Modbus devices or it can be used to bridge Modbus serial devices over TCP/IP
network.
The Modbus/RTU and Modbus/ASCII protocols define how a “master” device polls
one or more “slave” devices to read and write real-time data over RS-232, RS-422, or
RS-485 serial data communication. The simplicity of Modbus/RTU not only allows
rapid implementation, but can also remain flexible enough to be applied in virtually all
industrial situations.
During Modbus network communication, the protocol determines how each controller
will know its device address, recognize a message addressed to it, determine the
kind of action to be taken, and extract any data or other information contained in the
message. If a reply is required, the controller will construct the reply message and
send it back using Modbus protocol.
The way controllers communicate with each other is by using a master-slave tech-
nique, in which only one device (the master) can initiate queries. The other devices
(the slaves) respond by supplying the requested data to the master, or by taking the
action requested in the query. Typical master devices include host processors and
programming panels. Typical slaves include programmable controllers.
It is the master that can address individual slaves and initiate a broadcast message
to all slaves. On the other hand, slaves return a response to queries that are
addressed to them individually. Responses are not returned to broadcast queries
from the master.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Advantech EKI-1221 and is the answer not in the manual?

Advantech EKI-1221 Specifications

General IconGeneral
BrandAdvantech
ModelEKI-1221
CategoryGateway
LanguageEnglish

Related product manuals