7.3 Standards and r egulations
The router complies with the following standards and regulations.
S
tandards and regulations
R
adio
ET
SI EN 301 511 V12.5.1, ETSI EN 301 908-1 V11.1.1,
ETSI EN 301 908-2 V11.1.1, ETSI EN 301 908-13 V11.1.1,
ETSI EN 303 413 V1.1.1, ETSI EN 300 328 V2.1.1
EMC ET
SI EN 301 489-1 V2.2.0, ETSI EN 301 489-19 V2.1.0,
ETSI EN 301 489-52 V1.1.0, ETSI EN 301 489-17 V3.1.1
Saf
ety
EN
60950-1, EN 62368-1, EN 50385, EN 62311
Environmental RoHS, Reach, WEEE
T
able 7: Standards and regulations
7.4 Type Tests and Environmental Conditions
Phenomena T
est
Descr
iption
T
est levels
Dr
y heat
TBD Oper
ation
+70
C
Cold TBD Oper
ation
Storage
-30
C
-30
C
Dam
p heat
TBD +70
C,
rel. humidity 95%
T
emperature variation
TBD c
hange -30
C / +70
C
T
able 8: Type tests and environmental conditions