Step 4: Connect the power adapter to the LCD screen’s power socket. The display will then power
up.
The LCD will begin to register the outdoor sensor and receive weather data. Refer Figure
37.
Figure 37
Note, the wind direction will read approximately 180º S. This needs to be recalibrated for
the Southern Hemisphere.
Step 5:
Enter the Calibration Mode.
Press or key to select Wind Direction which will be approximately 180º. Press
or key and or key to set this value to 000º.