23
IREPPY - 1404 - 4238051_01
RePuro170
0
50
100
150
200
250
300
350
400
0 20 40 60 80 100 12 0 140 160 180
60dB(A)
56dB(A)
50dB(A)
64dB(A)
[m³/h]
⑦
⑰
⑳
⑭
⑪
[Pa]
RePuro170 - Sound power output at supply opening
Air ow
Available stac pressure
Sound power
Air ow curve - Available stac
pressure
RePuro170
[m³/h]
0
50
100
150
200
250
300
350
400
0 20 40 60 80 100 120 140 16 0 180
[Pa]
⑰
⑳
⑭
56dB(A)
60dB(A)
64dB(A)
50dB(A)
RePuro170 - Sound power output at intake opening
Air ow
Available stac pressure
Sound power
Air ow curve - Available stac
pressure
RePuro170 - Heat recovery efficiency *
[m³/h]
84
86
88
90
92
94
96
98
100
0 20 40 60 80 100 120 140 160 180
%
RePuro170
* Recovery
eciency
(winter)
EN 308
Extract air
25°C db
27% RH
Supply air
5°C db
50% RH
Supply air ow
=
Intake air ow
Air ow
Ecienza %