EasyManuals Logo

Agilent Technologies 4395A Service Manual

Agilent Technologies 4395A
343 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #316 background imageLoading...
Page #316 background image
Error
Messages
in
Alphabetical Order
269
COMPENSA
TION ABOR
TED
Comp
ensation
data acquisition
pro cess
is ab
orted.
267
COMPENST
A
TION
REQUIRED
Comp ensation
is required.
Perform
compansation
to
obtain
comp
ensation
data.
50
CONT
SWITCHING
MA
Y
DAMA
GE MECH
SW
RF
output
po
wer
switch,
input atten
uator
switc
h
at
input
R/A/B,
or
in
ternal
mec
hanical
switc
h
in
the
S-parameter
test
set
is
switc
hing
sw
eep
b
y
sweep,
because
RF p
ow
er
lev
el
or
the
input
atten
uator
setting
is
dierent
bet
ween
tw
o
c
hannels
and
the
dual
c
hannel
is
turn
on,
or con
tinuous
trigger
mo
de
is
selected
after
full
2-p
ort
calibration
is
p
erformed
when
4395A
is
used
with
the
S-parameter
test
set.
T
o
a
v
oid
premature
w
earing out
of the
output p
o
w
er
switc
h,
input
atten
uator
switch,
or in
ternal switc
h
of
the
S-parameter
test
set,
c
hange
trigger
typ
e
to
HOLD,
SINGLE,
or
NUMBER
of
GR
OUP
to
hold
sw
eep
after
measuremen
t
required.
Or,
for
example,
turn
o
the
dual
c
hannel,
or
set
the
p
o
w
er
lev
el
and
the input
atten
uator
of
b
oth
c
hannels
to
the
same
setting.
135
COUPLED
CHAN
-
BETWEEN
NA&NA
OR
ZA&ZA
The
analyzer
t
yp
es
of
b
oth
c
hannels
must
be
the
net
w
ork
analyzer
mo
de
or
imp
edance
analyzer
mo
de
when
the
coupled
c
hannel
is
turned
on.
It
is
not
p
ossible
to
turn the
coupled
c
hannel on
in
sp
ectrum
analyzer
mo
de.
74
CURRENT
EDITING
SEGMENT
SCRA
TCHED
The
curren
t
editing
segmen
t
for
the
list
table
and
the
limit line
is
scratc
hed
when
the
follo
wing
cases
o
ccur
(
GPIB
only
)
:
When
EDITLIST
(edit
list table)
command
is
receiv
ed
while
editing
a
segmen
t
for
the
list
table.
When
EDITLIML
(edit
limit
line)
command is
received
while editing
a segmen
t
for
the
limit
line.
Send
LIMSDON
(limit
segmen
t
done)
or
SDON
(segmen
t
done)
to
terminate editing
segment.
16
CURRENT P
ARAMETER NOT
IN CAL
SET
GPIB only.
Correction is not v
alid for the selected measuremen
t
parameter.
D
0
230
Data corrupt or stale
Possibly in
valid data. New reading started but not completed since last access.
0
225
Data out of memory
The analyzer has insucient memory to p erform the requested op eration.
Messages-4

Other manuals for Agilent Technologies 4395A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 4395A and is the answer not in the manual?

Agilent Technologies 4395A Specifications

General IconGeneral
BrandAgilent Technologies
Model4395A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals