EasyManuals Logo

Agilent Technologies 8163B Programming Guide

Agilent Technologies 8163B
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #259 background imageLoading...
Page #259 background image
GPIB Error Strings Error Codes
Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition 259
Standard -109
"Missing parameter"
[Fewer parameters were recieved than required for the header]
Standard -112 "Program mnemonic too long"
[The header contains more than twelve characters (see IEEE 488.2,
7.6.1.4.1).]
Standard -113
"Undefined header"
[The header is syntactically correct, but it is undefined for this specific de-
vice; for example, *XYZ is not defined for any device.]
Standard -120
"Numeric data error"
[This error, as well as errors -121 through -129, are generated when pars-
ing a data element which appears to be numeric, including the nondecimal
numeric types. This error message is used if the device cannot detect a
more specific error.]
Standard -121
"Invalid character in number"
[An invalid character for the data type being parsed was encountered; for
example, an alpha in a decimal numeric]
Standard -123
"Exponent too large"
[The magnitude of the exponent was larger than 32000 (see IEEE
488.2,7.7.2.4.1).]
Standard -124
"Too many digits"
[The mantissa of a decimal numeric data element contained more than 255
digits excluding leading zeros (see IEEE 488.2, 7.7.2.4.1).]
Standard -128
"Numeric data not allowed"
[A legal numeric data element was received, but the device does not ac-
cept one in this position for the header.]
Standard -131
"Invalid suffix"
[The suffix does not follow the syntax described in IEEE 488.2, 7.7.3.2, or
thesuffix is inappropriate for this device.]
Standard -134 “Suffix too long”
[The suffix contained more than 12 characters (see IEEE 488.2, 7.7.3.4).]
Standard -138
“Suffix not allowed”
[A suffix was encountered after a numeric element which does not allow
suffixes.]
Standard -141
“Invalid character data”
[Either the character data element contains an invalid character or the par-
ticular element received is not valid for the header.]
Standard -148
“Character data not allowed”
[A legal character data element was encountered where prohibited by the
device.]
Table 18 Overview for Supported Strings
New/Old/Standard
Error
Number String

Table of Contents

Other manuals for Agilent Technologies 8163B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8163B and is the answer not in the manual?

Agilent Technologies 8163B Specifications

General IconGeneral
BrandAgilent Technologies
Model8163B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals