Specific Command Summary Specific Commands
Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition 45
:DISPlay
:BRIGhtness/? Controls or queries the current display brightness. page 186
:CONTrast/? Controls or queries the current display contrast. page 186
:ENABle/? Switches the display on or off, or queries whether the display is
on or off.
page 187
:LOCKout/? Sets or queries local lockout mode. page 187
:FETCh[n][:CHANnel[m]][:SCALar]
:POWer[:DC]? Returns a power value from a sensor. page 87
:RETurnloss? Returns the current return loss value. page 87
:MONitor? Returns the current power value from the monitor diode within a
return loss module.
page 88
:INITiate[n]:[CHANnel[m]]
[:IMMediate] Starts a measurement. page 88
:CONTinuous/? Starts or Queries a single/continuous measurement. page 89
:LOCK/?
Switches the lock on/off or returns the current state of the lock. page 80
:INPUT[n][:CHANnel[m]]
:ATTenuation/? Sets or returns the attenuation factor for the instrument. page 148
:OFFset/? Sets or returns the offset factor for the instrument. page 149
:OFFset:DISPlay Sets the offset factor so that attenuation factor is zero. page 149
:OFFset:POWermeter Sets the offset factor to the difference between the power mea-
sured with a powermeter and with the monitor diode.
page 150
:ATTenuation:SPEed/? Sets or queries the filter transition speed page 150
:WAVelength/? Sets or queries the modules attenuation wavelength page 151
:OUTPut[n][:CHANnel[m]]
:APMode/? Sets or queries whether power setting or attenuation value has
been changed.
page 151
:APOWeron/? Sets or queries the shutter status at power on. page 157
:ATIMe/? Sets or queries the powermeter averaging time. page 157
:CONNection/? Selects or returns Analog Output parameter. page 113
:CORRection:COLLection:ZERO Zeros the offsets of attenuators powermeter page 157
:CORRection:COLLection:ZERO:ALL Zeros all available powermeter channels in mainframe page 158
Table 4 Specific Command Summary (continued)
Command Description Page

Table of Contents

Other manuals for Agilent Technologies 8163B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8163B and is the answer not in the manual?

Agilent Technologies 8163B Specifications

General IconGeneral
BrandAgilent Technologies
Model8163B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals