Chapter 6 Application Programs
Example Program for Excel 97
128
T o write an Excel macro you must first open a module in Excel. Go to the
View
menu, choose
Toolbars
, and then select
Control Too lbox
. The
Control Toolbox
dialog box appears. Select the
Command button
in the dialog box. Click cell
A1 and drag across the cell B3. The
CommandButton1
” box is created. To
change the button name, click the right mouse button on that button and then
se le ct Pro pe rt ie s. T he
Properties
dialog box appears. In the
Properties
dialog,
change the “(nam e)” and “caption” to “Diode”. To try the example for
characterizing a diode, type “Voltages” in cell A4 and “Current” in cell B4. In
cell A5 type 0.6. Fill in the cells A5 to A15 in 0.02 increments so that cell A15
contains 0.8.
To enter the “Diode macro example in this section, go to the
View
menu,
choose
Toolbars
, and then
Visual Basic Editor
icon. The “
Code window
appears. Then type the text as shown on page 139 into t he
[Moudle1 (code)]
window. To ente r the declaration for Windows
®
95/NT, go to the
Insert
menu,
choose
Module
. The
Module window
” appears. Then type the text as shown
starting on page 141. This module will configure all of the overhead required
to communicate w ith the power supply over the interface. Choose the
preferred interface by setting “bGPIB=” to “True” or “False” and change the
GPIB address or RS-232 port in the routine “OpenPort( )’’ contained in the
module.
To run t he macro, return back to the
Excel
window and select the
Run Macro
button in the dialog box and choose the macro name, and then cl i ck on the
Run
button . The power supply will reset to power on condition and then step
through the voltages in the worksheet. After each step the current is measured,
and recorded in the worksheet.
Make any changes necessary to suit your application in the “Diode module.
You must enter the information in the modules exactly as shown or error will
be generated. If several system errors occur while attempting to run a macro,
you may have to reboot your PC to get the GPIB port or RS-232 port to work
properly.
Note To use the example with Window
®
3.1, you will need to modify the declarations at
the top of the module. Change ‘visa32.dllto ‘visa.dll’ in all declarations.

Table of Contents

Other manuals for Agilent Technologies E3634A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E3634A and is the answer not in the manual?

Agilent Technologies E3634A Specifications

General IconGeneral
BrandAgilent Technologies
ModelE3634A
CategoryPower Supply
LanguageEnglish

Related product manuals