Installation Note E8364-90024 17
Analyzers with Hardware Options UNL, 014, and 080 Only
Refer to Figure 12 for this portion of the procedure. The new parts referenced in this
procedure are listed in Table 1 on page 4.
Install the following cables (provided) in the order listed.
• Wire harness 8121-0966 A45 reference switch
① to A16 test set motherboard J31
• Wire harness 8121-0966 A46 reference switch
② to A16 test set motherboard J30
• W96 E8364-20127 A45 reference switch to A46 reference switch
• W97 E8364-20121 A46 reference switch to REFERENCE 1 SOURCE OUT
• W98 E8364-20123 A45 reference switch to REFERENCE 1 RCVR R1 IN
• W99 E8364-20154 A45 reference switch to A28 channel R1 mixer
• W95 E8364-20119 A46 reference switch to channel R1 detector
• W71 E8364-20155 REFERENCE 2 RCVR R2 IN to A29 channel R2 mixer
Figure 12 Cable Installation, Analyzers with Options UNL, 014, and 080