15-4 EB AT-RP-4GU EN
Annex
Table 15-5: Ancillary attachments
SIZE
1
THREAD TIGHTENING TORQUE (Nm)
AA 0
M5 4 ÷ 5
AA 1
AA 2
AA 3
AA 4
AA 5 M6 8 ÷ 9
NOTE:
1.
Refer to section 2.1 ‘Actuator nameplate sample‘.
15.3 Lubricants
The 4
th
GU actuators are factory lubricated for the life of the
actuator in normal working conditions.
Î Refer to the data sheet [RP10600E] for Lubricant type in
relation to the different working temperature ranges.