Installation
GasEye Cross Duct
Operating i
nstructions,
0
5
/202
1
37
9. Using the provided Allen
key, turn the two screws
WITHOUT springs until
the light spot reaches the
center of the crosshair.
NOTE! If at any moment the
alignment screws become loose,
please tighten the screw with
spring on the opposite side.
Figure 31. Proper adjusting of the light
spot.
10. Replace the coarse
aligning unit with the fine
aligning unit. Make sure
that the crosshair is
oriented just like in the
picture (in line with the
aiming tool screw and the
purging inlet in flange).
Figure 32. Crosshair orientation.