Maintenance
2020 Flying Cloud 8-21
25FB Flying Cloud (30 Amp)
Main Circuit, 30 Amp
Circuit 1, 20 Amp
A Air Conditioner 16.0 Amps
Circuit 2, 15 Amp
B Converter (Wired Internally) 8.0 Amps
Circuit 3, 15 Amp
C Microwave Receptacle 12.0 Amps
Circuit 4, 15 Amp
D Inverter Receptacle 0.0 Amps
E Inverter 0.0 Amps
F RS Bedroom TV Receptacle 0.25 Amps
G Main Living Area TV Receptacle 0.25 Amps
H Dinette Receptacle 1.5 Amps
H Dinette Receptacle - CSA 1.0 Amps
J Blu-Ray Player Receptacle 0.15 Amps
Circuit 5, 15 Amp
K Water Heater (Wired Direct) 12.0 Amps
Circuit 6, 15 Amp (GFCI)
L CS Bedroom NS Receptacle 1.5 Amps
L CS Bedroom NS Recept - CSA 1.0 Amps
M Bathroom Receptacle 1.5 Amps
M Bathroom Receptacle - CSA 1.0 Amps
N Galley Receptacle 1.5 Amps
N Galley Receptacle - CSA 1.0 Amps
P Galley Endpanel Receptacle 1.5 Amps
P Galley Endpanel Recept - CSA 1.0 Amps
R Outside Receptacle 1.5 Amps
R Outside Receptacle - CSA 1.0 Amps
S Refrigerator Receptacle 2.7 Amps
Remote Generator Hookup Circuit
T 30 Amp Power Inlet
U 30 Amp Transfer Switch UL - CSA Rated
(Attached to back of Power Center)
DC to AC 1000W Inverter Rated at 8.5 Amp
Inverting
15 Amp Fuse for Overcurrent. Transfer Switch rated
at 15 Amp. UL 458 Tested. ULC