Relay Switch SettingRelay Switch Setting
You can configure the relay switch(es) and DTMF for the door access on the web Access ControlAccess Control
> Relay> Relay interface.
TypeType : Determine the interpretation of the Relay Status regarding the state of the door:
Default StatusDefault Status: ALowstatus in the Relay Status field indicates that the door is
closed, while “Highindicates that it is opened.
Invert StatusInvert Status: ALowstatus in the Relay Status field indicates an opened door,
while “Highindicates a closed one.
ModeMode: Specify the conditions for automatically resetting the relay status.
MonostableMonostable: The relay status resets automatically within the relay delay time after
activation.
Bistable:Bistable: The relay status resets upon triggering the relay again.
Trigger Delay(Sec)Trigger Delay(Sec): Set the delay time before the relay triggers. For example, if set
to 5 seconds, the relay activates 5 seconds after pressing the Unlock button.