Wiegand Input Data OrderWiegand Input Data Order: Set the Wiegand input data sequence between Normal and
Reversed. If you select Reversed, then the input card number will be reversed.
Wiegand Output Data Order:Wiegand Output Data Order: Determine the sequence of the card number.
NormalNormal: The card number is displayed as received.
ReversedReversed: The order of the card number is reversed.
Wiegand Output Basic Data OrderWiegand Output Basic Data Order: Set the sequence of the Wiegand output data.
NormalNormal: The data is displayed as received.
ReversedReversed: The order of the data bits is reversed.
Wiegand Output CRC EnabledWiegand Output CRC Enabled: It is enabled by default for Wiegand data inspection.
Disabling it may lead to integration failure with third-party devices.
Integration with MilestoneIntegration with Milestone
If you want the door phone to be monitored by Milestone or any third-party devices that have been
integrated with Milestone, you need to enable the feature.
Enable it on the Surveillance > ONVIF > Advanced SettingSurveillance > ONVIF > Advanced Setting interface.
Integration via HTTP APIIntegration via HTTP API
HTTP API is designed to achieve a network-based integration between the third-party device and
the Akuvox device.
Set it up on the web Security > HTTP APISecurity > HTTP API interface.