Troubleshooting
Heating or cooling doesn’t turn on when the
setpoint is above or below the room temperature
To prevent damaging the compressor, the thermostat
inserts a delay when cycling the compressor. If you
think the system should be on and it’s not, change the
setpoint to 2 degrees beyond the current setpoint
and wait 5 minutes to see if the system turns on.
If not, contact a local HVAC professional.
Heat pump is “cooling when it should be heating”
or “heating when it should be cooling”
Some heat pumps use the O terminal, while others
use the B terminal. Try switching the O or B wire
to the opposite terminal. Contact a local HVAC
professional for further assistance.
Thermostat buttons flash amber and screen
does not illuminate
The batteries in your thermostat are extremely low.
Install fresh batteries immediately.
Bypassing wire detection
If the automatic wire detection feature is not
correctly identifying your wires, please proceed
to bypass the automatic wire detection.
On the wiring detection screen, select NO.
The thermostat will display Check Wiring
and Reinstall. Select BYPASS and continue
through the remaining prompts to manually
configure the thermostat. You will need to
know the system type, heat type, and number
of stages to complete the installation.
Locating the INSTALLER (setup) menu
The initial setup menu can be accessed at any time:
1. Press the MENU button.
2. Select SETTINGS.
3. Select INSTALLER.