Loading...
Chassis Features
Page 24 7450 ESS-7
9 ACO/LT The Audible Alarm Cutoff/Lamp Test button verifies the operability of
LEDs. When pressed, the LEDs should temporarily illuminate. This
button also turns off all external alarm relay control bits until the next
new alarm condition.
The LEDs blink when the button is depressed.
10 Mgmt Link • Amber: 10 Mb/s
• Green: 100 Mb/s
• Unlit: Operationally down.
Data • Green (blinking): RX/TX activity.
• Amber (blinking): Error condition.
11 Compact Flash #1 (Slot) • Default filename: cf1:
• See the Compact Flash LED description for the status of a compact
flash slot.
• To eject a flash card, gently depress the ejector button until the flash
card releases.
12 Compact Flash #2 (Slot) • Default filename: cf2:
• See the Compact Flash LED description for the status of a compact
flash slot.
• To eject a flash card, gently depress the ejector button until the flash
card releases.
13 Compact Flash #3 (Slot) • Default filename: cf3:
• This slot should be used to download the boot and configuration
images.
• See the Compact Flash LED description for the status of a compact
flash slot.
• The ejector button for Compact Flash Slot #3 is slightly recessed. Insert
a small object such as a pen tip to depress the button.
Compact flash slot locking
mechanism
When engaged, the locking mechanism prevents the accidental jostling or
removal of the flash card inserted in Compact Flash Slot #3.
Table 5: SF/CPM Field Descriptions (Continued)