EasyManua.ls Logo

Alcatel-Lucent 7450 ESS-7 - CPM Switchover; Table 27: Revertive, Non-Revertive Timing Reference Switching Operation; System Management

Alcatel-Lucent 7450 ESS-7
537 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 224 7450 ESS OS Basic System Configuration Guide
CPM Switchover
During a switchover, system control and routing protocol execution are transferred from the active
to the standby CPM.
An automatic switchover may occur under the following conditions:
A fault condition that causes the active CPM to crash or reboot.
The active CPM is declared down (not responding).
Online removal of the active CPM.
A manual switchover can occur under the following conditions:
To force a switchover from an active CPM to a standby, use the
admin redundancy
force-switchover
command. You can configure a batch file that executes after
failover by using the config system switchover-exec and admin redundancy force-
switchover now CLI commands.