Page 110 7450 ESS OS Basic System Configuration Guide
filter
Syntax filter
Context monitor
Description This command enables the context to configure criteria to monitor IP and MAC filter statistics.
ip
Syntax ip ip-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]
Context monitor>filter
Description This command enables IP filter monitoring. The statistical information for the specified IP filter entry
displays at the configured interval until the configured count is reached.
The first screen displays the current statistics related to the specified IP filter. The subsequent statistical
information listed for each interval is displayed as a delta to the previous display.
When the keyword rate is specified, the "rate per second" for each statistic is displayed instead of the delta.
Monitor commands are similar to show commands but only statistical information displays. Monitor
commands display the selected statistics according to the configured number of times at the interval
specified.
Parameters ip-filter-id — Displays detailed information for the specified filter ID and its filter entries.
Values 1 — 65535
entry entry-id — Displays information on the specified filter entry ID for the specified filter ID only.
Values 1 — 65535
interval secondsConfigures the interval for each display in seconds.
Default 5 seconds
Values 3 — 60
repeat repeat Configures how many times the command is repeated.
Default 10
Values 1 — 999
absolute — When the absolute keyword is specified, the raw statistics are displayed, without processing.
No calculations are performed on the delta or rate statistics.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead of the
delta.
Sample Output
A:ALA-1>monitor# filter ip 10 entry 1 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for IP filter 10 entry 1
===============================================================================
At time t = 0 sec (Base Statistics)