the system as well as any external EPS48 power connections that may be connected. Then
remove the rear metal panel of the power supply block and disconnect the batteries.
High leakage current
A permanent earth connection is essential before making TRT/TNV-3
telecommunication network connections.
In the case of a poor earth connection, it is MANDATORY to disconnect the
telecommunications accesses before reconnecting the equipment to earth. It is then necessary
to verify that all the connections have been made correctly.
Before removing any board that provides access to a telecommunications
network of class TRT/TNV-3, make sure you disconnect the links. Reconnect the links
once the board is re-inserted.
Installation of DECT bases
For further information on recommendations relating to the exposure of the public to the
electromagnetic field, refer to "Installation of DECT bases".
1.2.1.3 Declaration of Conformance With Directives
This equipment is designed to be connected to the public telephone network using the
appropriate interfaces.
The EC labeling indicates that this product conforms to the EC directives currently in force, in
particular:
- 89/336/EEC (Electromagnetic compatibility)
- 73/23/EEC (Low Voltage)
- R&TTE 1999/5/EC compliance
- 1999/519/EC (Specific Absorption Rate)
1.2.1.4 Interface Classification
1.2.1.4.1 OmniPCX Office RCE Small, Medium, Large
SELV: Safety Extra Low Voltage TNV-3: Telecommunication Network Voltage
1-3