Once the IBS finishes the downloading, the system starts the initialization.
The system synchronizes the signals of the IBSs so that handovers are possible. The system
selects the T0, T2, or CPU main board clock as the source.
Then the system sends the following data:
- Fixed part capabilities (Full slot, frequency control, page repetition, setup on dummy, basic
A field setup): value sent = 0x007910
- Line length: Short line
- Frequency plan (2 bytes)
Some countries have shifted DECT frequencies. In order to be compatible with all frequency
bands in the different countries, 4 types of initialization of frequency plans are available:
Europe, Latin America, The United-States and China.
table 4.43: RF Band Europe
Channel TX Freq RX Freq
0 1897.344 1898.206
1 1895.616 1896.480
2 1893.888 1894.752
3 1892.160 1893.024
4 1890.432 1891.296
5 1888.704 1889.566
6 1886.978 1887.840
7 1885.248 1886.112
8 1883.520 1884.384
9 1881.792 1882.656
Note 1:
By default, all frequencies used
Value sent to IBS: 0x3FF
0000 0011 1111 1111
table 4.44: RF Band China
Channel TX Freq RX Freq
0 1918.060 1918.944
1 1916.352 1917.216
2 1914.624 1915.446
3 1912.898 1913.760
4 1911.188 1912.032
5 1919.440 1910.304
6 1907.712 1908.576
7 1905.964 1906.848
8 1904.256 1905.120
  &'(
     
4-97

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Office RCE Small and is the answer not in the manual?

Alcatel-Lucent OmniPCX Office RCE Small Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniPCX Office RCE Small
CategoryServer
LanguageEnglish

Related product manuals