Booting OmniSwitch 6450 Switches Monitoring the Chassis
OmniSwitch 6450 Hardware Users Guide September 2015 page 5-5
Viewing the Power Supply Status
To check the status of the power supply, use the show power command. For example:
-> show power
Slot  PS   Wattage   Type     Status   Location
----+----+---------+------+-----------+----------
 1    1      30      AC       UP        Internal
Additional Monitoring Commands
Using LEDs to Visually Monitor the Chassis
The front and rear panel of provides status LEDs that are useful in visually monitoring the status of the 
switches. LEDs include:
• Ethernet Port LEDs
• System Status LEDs
• Combo Port Status LEDs
For tables showing LED states operating normally, refer to “OmniSwitch 6450 LED Status” on page 3-32.
CLI Commands Used for Monitoring a Chassis
show cmm Displays the basic hardware and status information for primary and 
secondary management modules (if applicable).
show ni Displays the basic hardware and status information for individual mod-
ules. If the switch is a standalone, information for the stand alone 
switch displays.
show module Displays the basic information for individual modules. If the switch is a 
standalone, information for the stand-alone switch displays.
show module long Displays the detailed information for individual modules. If the switch 
is a standalone, information for the standalone switch displays.
show module status Displays the basic status information for individual modules. If the 
switch is a standalone, information for the standalone switch displays.