Residential HRV/ERV
16
Your HRV/ERV will reduce indoor humidity levels when outdoor air is drier than indoor air.
This usually occurs during the heating season when outdoor temperatures are less than 10°C
(50°F), as shown in the following table:
RECOMMENDED RELATIVE HUMIDITY TO PREVENT INDOOR CONDENSATION*
OUTSIDE AIR TEMPERATURE RELATIVE HUMIDITY
0°C to 10°C (32°F to 50°F) 45% - 50%
-6°C to 0°C (21°F to 32°F) 40% - 45%
-12°C to -6°C (10°F to 21°F) 35% - 40%
-18°C to -12°C (0°F to 10°F) 25% - 30%
-24°C to -18°C (-11°F to 0°F) 20% - 25%
Under -24°C (-11°F) Under 20%
*Values according to the type of construction and fenestration of your house.
ASHRAE 62.2 standards recommend maintaining a relative humidity rate between 30%
and 60%. The average person is comfortable between 30-50% relative humidity (RH).
Aldes oers several wall controls with a dehumidistat function. Please refer to the wall control
user guide for detailed information.
IV. INSTALLATION
Caution : Open the door of the unit and remove any styrofoam inserts and installation
parts before installation.
What’s Included
Verify that all parts have been included with the shipment. If any parts are missing, notify
your distributor as soon as possible. Note: Quantity of parts may vary depending on model
of air exchanger (e.g., single or double drain)
• Heat or Energy Recovery Ventilator
• Parts Bag
» (4) - springs
» (4) - hooks
» (8) - sheet-metal screws for hooks
» (4) - wood screws for hooks
» (2) - 3/8”-1/2” universal drains
» (2) - seal grommets (optional)
» (2) - nuts
» (4) door caps (to plug static pressure taps)
» Assembly chains
» Drain tubing
» Tee connector for drain tubing (quantity varies according to model)