42
English
MULTIJET PRO
TECHNICAL SPECIFICATIONS
POWER SUPPLY
- Selector switched to 110VAC
. Voltage range: ................................................................................. 100V - 130V
. Maximum power consumption: .................................................................. 300W
. General fuse ....................................................................................... 5 A (5X20)
- Selector switched to 220VAC
. Voltage range: ................................................................................. 200V - 240V
. Maximum power consumption: .................................................................. 300W
. General fuse ....................................................................................... 4 A (5X20)
FREQUENCY: .......................................................................................... 47Hz - 63Hz
PRESSURE RANGE
. Maximum: ................................................................................4,5 bar to 5,5 bar
. Minimum: .................................................................................0,2 bar to 0,3 bar
ULTRASOUND
. Frequency: ........................................................................................... ~40KHz
. Potency: ................................................................................................... ~50W
Note: The ultrasound behavior depends of the electric voltage on the outlet.
RESISTANCE READING (ONLY ON TEST INJECTORS OUTPUT)
. Resistance < 0,5
- short circuit
. Resistance >= 36,5
- open circuit
AUXILIARY OUTLET - Available on limited series only.
. Voltage:................................................................Same voltage of power supply
. Maximum current allowed: ............................................................................ 2A
NOTE: Using this outlet is recommended for supply of exclusive accessories for this equipment.