9. ELECTRICAL: Connect machine to an electrically
grounded circuit that is fused or circuit breaker
protected. The circuit must match that specified in
the ELECTRICAL section under MODEL
SPECIFICATION.
10. EXTENSION CORD: The use of an extension cord
that has undersize wire compared to the amp draw
of your machine will adversely limit the starting load
carrying abilities of the motor and machines
performance. Use only 3-wire extension cords that
have 3-prong plugs and 3-pole cord connectors that
accept the plug from the product. Use only extension
cords that are intended for outdoor use. These
extension cords are identified by a marking
“Acceptable for use with outdoor appliances; store
indoors while not in use.” Use only extension cords
having an electrical rating not less than the rating of
the product. Do not use damaged extension cords.
Use an extension cord in good repair free of frays or
cracks in the outer covering. Do not abuse extension
cord and do not yank on any cord to disconnect.
Keep cord away from heat and sharp edges. Always
disconnect the extension cord from the receptacle
before disconnecting the product from the extension
cord.
11. THREE PHASE INSTALLATION: Three phase power
must be connected so that the motor has clockwise
rotation as you look at the shaft end of the motor.
WATER INSTALLATION
1. WATER TEMPERATURE VARIATION: On
machines not equipped with a temperature control
device, the temperature of the discharged water is
dependant on the incoming water temperature. Some
minor adjustment to the fuel input may be required if
the incoming water is significantlY different than 50
degrees fahrenheit.
2. WATER CONDITIONS: Local water conditions affect
the coil and spray tip more adversely than any other
element. In areas where troublesome conditions may
exist with like equipment (such as water heaters),
we recommend the use of a water softener.
WARNING: This machine emits carbon monoxide,
and deadly gas, and must be vented if used in an
enclosed area. Improper venting can cause poor
combustion, delayed ignition, down drafts, and the
possibility of freezing the coil. Contact your distributor
or local heating and air conditioning dealer for proper
materials. Local codes must be observed.
The information contained herein is offered for
reference only. You must comply with local codes
and investigate through your gas and other utility
companies when installing, as there may be some
special local requirements you must comply with.
Also see ANSI Z223.
1. DRAFT DIVERTERS: (STACKED CLEANERS)
Oil fired machines use a force air burner. The oil burner
can be influenced by “Natural Draft” even though they
have their own fan. A Bell type draft diverter must be
used here also.
A. A draft diverter must be used on all cleaners that
are stacked. This includes any chimney even if
not expelled to the outside.
6
Supersedes 08-19-05 Z08-03940C 07-05-06 Z08-03940C
WARNING: ELECTRICAL SHOCK HAZARD
LE DANGER ELECTRIQUE DE CHOC
ADVERTENCIA: CHOQUE ELÉCTRICO
CHART FIGURES ARE BASED ON NOT MORE
THAN 100 FOOT.
(Based on Ambient Temperature of 86°F (30°C)).
*Use Amp Draw indicated the same or higher than your
machine output
EXAMPLE: Machine Amp Draw 51, use 55 (2 Conductor).
The thermostat type of cord shall be C, PD, E, EO, EN,
S, SO, SRD, SJ, SJO, SV, SVO, SP.
The thermo set plastic types shall be ET, ETT, ETLB,
ETP, ST, STO, SRDT, SJT, SJTO, SVT, SVTO, and SPTB.
COPPER WIRE
SIZE
MINIMUM AWG
16
15
14
12
10
8
6
4
2
MACHINE AMP
DRAW*
3 CONDUCTOR
WIRES
10
15
20
25
35
45
60
80
MACHINE AMP
DRAW*
2 CONDUCTOR
WIRES
13
18
25
30
40
55
70
95
VENTING
WARNING: CARBON MONOXIDE HAZARD
DANGER
MONOXYDE DE CARBONE
MONÓXIDO DE CARBONO
PELIGRO