5 Initial operation
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 21
5.4 Listing the configuration data of readers
The cfg command lists the configuration data of readers.
fieldservice@IF xxxx:~ cfg
Terminal configuration IF xxxx/4735 IT-2018.02.0-794-g91e557d6d26e Host: Ethernet
----------------------------------------------------------------
No B A HA TNo type HWU SWU display keys read.1 read.2 In/Out I/O
-- - - -- --------- ------- ----- ----- ------- ------ ------ --
1 1 A 1 0 IF611 3.00 7.b ../.... ....N. PSCR/P ...... ...... ++
2 1 B 2 0 IF600 3.00 7.c ../.... ...... LAP4 ...... ...... ++
----------------------------------------------------------------
Internet address: 172.18.12.65
Port-number: 2001
MPU board: phyCORE-AM335x
Text Description
B 3 bus interfaces with the terminal distribution, e.g. the factory-configured default
distribution of 6, 4 and 6 readers
A Alpha hardware address of the reader
HA Numeric hardware address with which the time/access program manages readers
TNo Host management number
The numbers are configured in the time recording/access control program and are
displayed after the data has been loaded.
type Device type, e.g., reader IF-xxx
HWU Hardware status, e.g., 2.04 for MPU hardware HCS12
SWU Software status, e.g. version 6.b
display Display type (type / line x columns)
keys Keypad type, e.g. N = numeric keypad, F = function keys
read.1 First reader type, e.g., PSCR/P for MIFARE readers
read.2 Second reader type, e.g., BCR for terminals with barcode reader
In/Out Configured RS-232 interface, e.g. >RKASS< for a cashbox
I/O - + = 1st I/O controller board for door control is ready for operation
+ - = 2nd I/O controller board (I/O expansion board) is ready for operation
+ + = 1st First I/O controller board and 2nd I/O controller board ready for operation
- - = Reader is operated without I/O controller board