5 Initial operation
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 22
5.5 Restarting the controller
Some changes require a restart of the controller. You can do this directly on the controller or with the
appropriate commands via the console.
Warm boot
A warm boot performs the following actions:
n
Close application
n
Restart application
Associated console command: oc -s or factory-reset application-restart
Reboot
A reboot performs the following actions:
n
Close application
n
Shut down operating system
n
Boot operating system
n
Restart application
1. Set switches:
2. Shortly press the Reset button
3. Wait until the RUN LED lights up again (procedure can take up to 30 seconds)
Associated console command: factory-reset reboot