Construction Mode
Construction Mode
Construction Mode is NOT required to operate lock. Construction Mode is used to allow access before the lock is captured and/or for
testing purposes before capturing.
• Enabled by default and after a factory reset.
• The lock will remain in Construction Mode until the mode is cancelled as described below.
• No access audits are captured while the lock is in Construction Mode.
To enter construction mode, present a valid construction credential. Any other construction credentials ordered at the same time or
programmed for your site work in the lock while it is in construction mode.
To exit construction mode, retract the bolt and then use the mobile app to capture the lock. All construction credentials are not valid once
the lock exits construction mode.
Factory Default Reset
A Factory Default Reset (FDR) returns the lock to the original settings as shipped from the factory. This removes congurations,
databases, and requires the lock to be re-captured. The FDR process does not remove the lock from your ENGAGE account.
1. Disconnect the batteries for at least ten (10) seconds.
2. Reconnect the batteries.
3. Wait for the lock to beep and ash three (3) times.
4. Within ten (10) seconds, rotate the iterior tail piece back and forth two (2) times.