74 Rockwell Automation Publication 442L-UM005B-EN-P - April 2017
Chapter 8 Commissioning
For stationary applications, check that the hazardous areas marked out
on the floor match the shapes of the protective fields that are stored in
the SafeZone Mini device and that any gaps are protected by additional
safety measures. For mobile applications, check that the moving vehicle
actually stops in a timely manner at the protective field boundaries that
are set in the SafeZone Mini device and listed on the information label
on the vehicle or in the configuration protocol. If you discover any non-
conformance of this function, the machine/system/vehicle must be
stopped immediately and checked by qualified safety personnel.