EasyManua.ls Logo

Alliance Laundry Systems CCN020HNF - No Extract (F and V-Speed Models)

Alliance Laundry Systems CCN020HNF
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Design 1 Only
19
F8266301ENR4
2. No Extract (F and V-speed Models)
CHM467S
No Extract (F and V-speed Models)
Is there an active
fault on the drive?
Refer to “No Rotation with Drive Fault” flowchart.
Yes
Is the correct voltage
present at the drive
terminals R/L1, S/L2
and T/L3?
Correct voltage at the drive.
No
No
Are any of the drive
output LEDs (RUN,
REV, SPD1, SPD2 or
SPD3) lit on the AP1
Output Board?
Yes
Check H13 and J16. Check wiring between AP2 Control
Logic Board and AP1 Output Board. Repair/replace as
necessary.
No
Refer to Washer-Extractor AC Adjustable
Frequency Drive Supplement for further test
information.
A
Yes
Is there an extract
step programmed?
Add/edit extract step in programming.
No
Is there a drain step
programmed before
the extract step?
Add/edit drain step in programming.
Yes
Yes
No
CHM467S