46
12. No Rotation with Drive Fault
CHM475S
No Rotation with Drive Fault
Is there an active
fault on the inverter
drive?
Determine what the fault is and act
accordingly. Refer to Inverter Drive
Supplement
Refer to “No Motor Rotation without
Drive Fault” flowchart.
No
Place machine back in service.
No
Yes
Yes
Power
down and wait
two minutes for the drive
to reset and power up.
Does the problem
persist?