Design 1, 2 and 3
41
F8266301ENR4
10. Abnormal Operation
CH
Abnormal Operation (water level, coast time, etc.)
Is the capacity jumper
configuration at H14 on
the AP1 Output Board
incorrect?
Use capacity information on schematic to
select correct jumper. Refer to Abnormal
Conditions Schematic.
Yes
Check pressure hose connections
to:
-Empty level pressure switch.
-Pressure transducer on AP1
output board.
-Three connections on plastic “T”.
Is the pressure hose connected?
No
Connect the pressure hoses..