Alliance Laundry Systems CCN020HNF - Door Fails to Unlock at End of the Cycle

Alliance Laundry Systems CCN020HNF
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Design 1, 2 and 3
F8266301ENR4
26
3. Door Fails to Unlock at End of the Cycle
Door Fails to Unlock at End of the Cycle
Is the solenoid
mechanically
bound?
Replace/adjust solenoid as necessary.
Yes
Is there
continuity through
low level water pressure
switch?
Unless the machine is rotating, the
control should open the door.
Yes
Is there water in the
machine?
No
Troubleshoot the drain.
Yes
Replace the AP1 Output Board.
No
B
A
No
CHM462S