© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
61
70417701
28. Low Power/Auto Shutdown D
Days Enable “LPSd”
This option allows the owner to enable or disable Low
Power/Auto Shutdown. Low Power or Auto Shutdown
duration are programmed using an external device or
network.
How to Program the Low Power/Auto
Shutdown D Days Enable
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP (∧) or the
DELICATES (∨) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
“AtSH” will appear in the display.
3. Press the LOW TEMP (∧) or the
DELICATES (∨) keypad to scroll through the
programmable options until “LPSd” appears in
the display.
4. When “LPSd” appears in the display, press the
START (enter) keypad. The current Low Power/
Auto Shutdown D Days Enable status will appear
in the display.
“on” = Option Enabled
“oFF” = Option Disabled
NOTE: The default value is oFF.
5. Press the LOW TEMP (∧) or the
DELICATES (∨) keypad to change the current
status.
6. Press the START (enter) keypad when the correct
setting appears in the display. The new value is
saved and the next option, “PFr”, will appear in
the display.
NOTE: To program “PFr” (Power Fail Reset),
refer to option 29. To program other options, refer
to the appropriate section.
How to Exit Programming Feature
Press the MED TEMP (<) keypad until the control
returns to Ready Mode.
29. Power Fail Reset “PFr”
This option allows the owner to set the amount of time
the control will store active cycle information in the
event of a power failure. The default setting for Power
Fail Reset is OFF. If Power Fail Reset is turned OFF,
the cycle will be saved.
How to Program Power Fail Reset
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP (∧) or the
DELICATES (∨) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
“AtSH” will appear in the display.
3. Press the LOW TEMP (∧) or the
DELICATES (∨) keypad to scroll through the
programmable options until “PFr” appears in the
display.
4. When “PFr” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current Power Fail Reset setting.
5. Press the LOW TEMP (∧) or the
DELICATES (∨) keypad to increase or decrease
the current number to the desired number
selected from Table 14.
6. Press the START (enter) keypad when the correct
number appears in the display. The new value is
saved and the next option, “IrA”, will appear in
the display.
NOTE: To program “IrA” (IR Access [On/Off]),
refer to option 30. To program other options, refer
to the appropriate section.
How to Exit Programming Feature
Press the MED TEMP (<) keypad until the control
returns to Ready Mode.