© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
69
70417701
Diagnostic Test Descriptions
Control Software Version Number Test
This option displays the control software version
number. To start test, control must be in the Testing
Mode. Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the START (enter) keypad. The display
will show “S xx” where “xx” is the software version
number.
To exit the Software Version Number Test, press the
MED TEMP (<) keypad. The control will return to the
testing mode.
Service Door Opening Test
This option tests the service door switch. To start test,
control must be in the Testing Mode. Refer to “How to
Enter Testing Feature” at the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show “S oP” when the service door switch is
open and “S CL” when the service door switch is
closed.
The service door switch has to be closed for at least
one second and opened for at least a half a second to
make a valid count. This test will add counts to the
service door opening counter for the audit and save the
date/time for each opening of the test.
To exit the Service Door Opening Test, press the
MED TEMP (<) keypad. The control will return to the
testing mode.
Coin Vault Opening Test
This option tests the coin vault switch. To start test, the
control must be in the Testing Mode. Refer to “How to
Enter Testing Feature” at the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show U oP” when the coin vault switch is open
and “U CL” when the coin vault switch is closed.
The coin vault switch has to be closed for at least one
second and opened for at least a half a second to make
a valid count. This test will add counts to the coin
vault opening counter for the audit and save the time/
date for each opening of the test.
To exit the Coin Vault Opening Test, press the
MED TEMP (<) keypad. The control will return to the
testing mode.
Coin Drop #1 Input Test
This option tests coin drop #1. To start test, control
must be in the Testing Mode. Refer to “How to Enter
Testing Feature” at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “C1xx”. The “xx” will show the number of
coins entered and will increment one for each coin
entered in coin drop #1.
NOTE: Coins entered in test mode will not
increment the total # of coins counter that is
accessed in the audit feature.
To exit the Coin Drop #1 Input Test, press the
MED TEMP (<) keypad. The control will return to the
testing mode.
Coin Drop #2 Input Test
This option tests coin drop #2. To start test, control
must be in the Testing Mode. Refer to “How to Enter
Testing Feature” at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “C2xx”. The “xx” will show the number of
coins entered and will increment one for each coin
entered in coin drop #2.
NOTE: Coins entered in test mode will not
increment the total # of coins counter that is
accessed in the audit feature.
To exit the Coin Drop #2 Input Test, press the
MED TEMP (<) keypad. The control will return to the
testing mode.
Start Pulse Test
This option tests the Start Pulse. To start test, control
must be in the Testing Mode. Refer to “How to Enter
Testing Feature” at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “Stxx”. The “xx” will show the number of
pulses entered. This test will add counts to the total
number of Start Pulses counter.
To exit the Start Pulse Test, press the MED TEMP (<)
keypad. The control will return to the testing mode.

Related product manuals