© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
70417701
70
Tumbler-on Temperature Test
This option tests the temperature inside the cylinder
while running a cycle.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the START (enter) keypad. The display
will show “F---” for degrees in Fahrenheit or “C---”
for degrees in Celsius. The “---” will show the degrees.
To exit the test, press the MED TEMP (<) keypad. The
control will then return to the testing mode.
Thermistor Temperature Test
This option displays the temperature sensed at the
thermistor in 3°F increments.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the START (enter) keypad. The display
will show “Fxxx” or “Cxxx”. The “F” will show
Fahrenheit, the “C” will show Celsius and the “xxx”
will show degrees. If control senses a shorted
thermistor, the display will show “SH”. If the control
senses an open thermistor, the display will show “oP”.
To exit this test, press the MED TEMP (<) keypad.
The control will return to the testing mode.