39Alvium USB Cameras User Guide V3.6.4
Compliance, safety, and intended use
For your safety and to improve camera performance, operate the camera:
Mounted to a base with a high thermal conductivity
With lens or other optical components mounted
With a heat sink mounted that has large surface areas (closed housing cameras
include a heat sink)
Using conductive media for camera and heat sink mounting
With active cooling of camera, mounting base, and heat sink, such as by
ventilation.
Reduce high ambient temperature. For example, in outdoor applications with
direct sunlight, provide shading by an enclosure.
Hardware option Housing
Components in the
cooling areas
1
Mainboard
2
Bare board
3
Not applicable
-20° C to +85° C
See model
Specifications on page
46.
Open housing
4
-20° C to +65° C
Closed housing Not applicable
1
See Mounting the heat sink on page 185.
2
Output by DeviceTemperature
3
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
questions, please visit www.alliedvision.com/en/support.
4
Temperature values must be observed for the housing and for the cooling areas.
Table 6: Operating temperature ranges for Alvium USB cameras
Figure 1: Setup to provide optimum heat dissipation
More information
For more information on heat dissipation, see the Optimum Heat Dissipation for
Housed Alvium Cameras application note at
www.alliedvision.com/en/support/technical-documentation/
alvium-usb-documentation.
Heat sink Camera housing Lens
Base
i