EasyManua.ls Logo

Allied Vision Alvium 1800 Series - Relative QE

Allied Vision Alvium 1800 Series
235 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75Alvium USB Cameras User Guide V3.6.4
Specifications
Relative QE
1800 U-130 VSWIR
Storage temperature -20° C to +85° C ambient temperature
Operating temperature
Hardware
option
Housing
Cooling areas
1
Mainboard
2
Bare board
3
Not applicable
-20° C to +85° C
-20° C to +85° C
Open housing
4
-20° C to +65° C
Closed housing -20° C to +65° C Not applicable
Relative humidity 0% to 80% (non-condensing)
Digital interface Micro-B USB 3.1 Gen 1 interface
Camera controls GenICam V2.0 (GenICam Access)
1
See Mounting the heat sink on page 185.
2
Output by DeviceTemperature
3
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
questions, please visit www.alliedvision.com/en/support.
4
Temperature values must be observed for the housing and for the cooling areas.
Figure 11: Alvium 1800 U-130 VSWIR (Sony IMX990) relative QE
Feature Specification
Table 26: Alvium 1800 U-130 VSWIR specifications (sheet 2 of 2)
0%
10%
20%
30%
40%
50%
60%
70%
80%
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
Quantum Eĸciency [%]
Wavelength [nm]
Sony IMX990, IMX991 ƌĞůĂƟǀĞ QE

Table of Contents