12
Additionaltemperaturehints
Thetem peratureandpressurelimitationslistedonpage5aresolelybasedonmechanicaltemperaturelimits
ofthehousingmaterialused.Dependingonthefluidpumped,themaximumsafeoperatingtemperatureof
thehousingmaterialcanbereducedsignificantly.
Ageneralaspectoflowertemperaturesis,that
below0°C(32°F)cold‐brittlingoftheelastomersusedwithin
thepumpscanresultsinacceleratedwear.Regardingthehousingmaterials,pleasenotethatPE‐otherthan
PP‐keeps itsmechanical strengthsat low temperaturesand PTFE keeps mechanicallystable as wellfor an
extended temperature range. ALMATEC pumps of the
E‐Series can therefore be operated safely as well
within low‐temperature installations: However, with liquids below 0°C (32°F) accelerated wear of internal
partshastobeaccepted.Moreover,freezing,boggingorcrystallisationofthefluidpumpedmustbeavoided,
especiallywithinthepump.Emptyingthepumpviathedrainage
system(optionalequipmentcodeR)maybe
ausefultooltoassistthis.
Please consider, that viscosity and specific gravity of most fluids change with temperature (most often
increasing at lower temperature). Depending on the application, this fact may not only result in result in a
reducedflowrate,thepump
mayevenbeunabletoprimethethickerand/or“heavier“fluidanymore.
Incaseofvaryingapplicati ontemperatures,thehousingbolttensionhastobecontrolledverythoroughly,as
variationslikethesecanchangetheeffectivetensionofthehousingboltsviathedifferentthermalexpansion
characteristicsofsingle.
Providingspareparts
Werecommendhavingsparepartkits“S”onstock.Theseincludetherelevantsparepartsforyourpump.