ALMATECPULSATIONDAMPERS,ETSeriesandETFSeries
The ALMATEC pulsation dampers series ET and ETF represents the latest generation of active pulsation
dampers.TheyarespeciallydesignedtobeusedalongwithALMATECairoperateddoublediaphragmpumps
oftheESeries.Ageneralaspecttobe
consideredis,thatapulsationdamperdecreasesthetotalcapacityof
thesystemdependingonthepointofoperation.
Beforeputting anALMATECpulsationdamperintooperation,make sure,thatthematerials ofconstruction
areresistanttothechemicaltobepumped.Tocheckthis,theexactdampercodeis
required.Thiscode,the
serialnumberandtheyearofconstructionarenotedontheidentificationplatesonthedamperitself.
Exampleofthedampertypecode:
ET 15 E A E ‐ F
FlangeconnectionDIN(F)orANSI(Fw)
Diaphragm E EPDM
material: N NBR
T
PTFE/EPDMcompound
TLPTFEconductive/EPDMcompound
TP PTFEmodified/EPDMcompound
Materialofdamper A PA
head:F PEconductive
Materialofdamperhousing: E PE
F PEconductive
T PTFE
U PTFEconductive
 Size,nominalconnectionsize: 10:3/8“,15:1/2“,25:1“,
40:11/2“,50:2“
ALMATECpulsationdamper,ETseries
Airsupplyconnection:ET10‐ET25:R1/8“,ET40/ET50:R1/4“
Max.operatingpressure: 7bar/100psig
Max.operatingtemperature: fordamperhousinginPE70°C/158°F
fordamperhousinginPTFEsizeET
10100°C/212°F,fortheothersizes
120°C/248°F(withdamperheadinPEconductive80°C/176°C)
For flammable liquids as well as for applications in explosion protected areas, only dampers made of
conductive plastic materials (code F resp. U) may be used. It is not necessary to ground the damper
separately,asthe
damperisconnectedconductivelytotheESeriespump,whichisconductiveandhastobe
groundeditself(pleaseseeATEXhintsonpage4).
In general, pump and damper are dispatched completely mounted. Still, they can be packed in separate
boxes,especially forthe biggersizes. Ifso, the
damperhasto bescrewed intothe threadatthetopof the
center housing carefully, but only until the damper is in contact with the pump. Exceeded tightening may
damagethethread.Besides,acorrectpositioningoftheOring[10]withinthegroovehastobeensured.
An ALMATEC
ETdamper can easily be attached to an ESeries pump at any time without changes of the
piping,providedthatthepumpisconfiguratedwithproductportsbothhorizontally.Makesurethattheplug,
center housing (item 13 in the exploded view of the pump) is in the right
position. For pumps delivered