42
We reserve the right to modify technical specifications without prior notice.
UK830300/170717 © Alpha-InnoTec GmbH
-F12 -F10 -F11
L Y2
A1
A2
4
1
5
2
P
3~PE/400V/50Hz
ASD
MOT
2
2
Charge/discharge/cooling mixer 1 closed
PEX
Accessories: Remote control
PE
-X4
PE
MIS
TB1
TA
External return sensor
MZ1/MIS
Sensor mixing circuit 1
no function
6-12 kW: C10 A
14-17 kW: C16 A14-17 kW: C16 A
3
Charge/discharge/cooling mixer 1 open
-X7
Overload protection; internally wired
EVU
TRL
HUP
TB1
L1
TB1
TA
GND
GND
Pump for mixing circuit 1
N
N
ASD
EVU
ASD
TRL
MA1/MIS
MZ1
4
Brine pressure pressostat; provided by cust. if necessary
External sensor
PE
ZW1
GND
Accessories: Transformer for dewpoint monitor
L1
Accessories with cooling option: Dewpoint monitor; bridge if not connected
1~N/PE/230V/50Hz
PE
RFV
UK831120a
L1
Energy supplier contact; closed on release; bridge if no blocking interval
B10 A
F10
GND
FP1
L2
Controller board; Attention: I-max = 6A/230VAC
Cut out controller unit
6-12 kW: C10 A
14-17 kW: C16 A14-17 kW: C16 A
RFV
PE
M
PEX
N
FP1
N
PE
A2
With cooling option: Room thermostat; bridge if not connected
Y3
GND
RFV
3-pol. Cut out compressor; Attention: Right-hand rot. field is mandatory!
Terminals in heat pump switchbox
BUP
Legend:
Function
Accessories: Process water sensor/thermostat
ZW1
VBO
VBO
Terminals
Control signal of additional heat generator 2 (alternative is general malfunction)
Control signal of additional heat generator 1; internally wired
-X0
Power supply compressor 3 x 400V; Attention: Right-hand rot. field is mandatory!
ZUP/ZIP
Y2
A2
M
Terminal strips on controller board (see sticker)
F11
T2
ZW2/SST
-X3
MA1
L3
Control 230V
X7:PE,L1,L2,L3
24V
-Y2
X7:PE,N,L1
230V
1
-Y3
3~N/PE/400V/50Hz
-T2
3
2
Auxiliary circulation pump / circulation pump
Brine water compact 6 - 17 kW
2
X7:PE,N,L1,L2,L3
X7
Auxiliary heating 3 x 400V
2
Brine circulation pump
Terminal strip in switchbox of heat pump; N/PE distribution for external 230V units
6 - 17 kW
X0-X4
TBW
EVU
Heating circuit circulation pump; internally wired
TBW
N
L2
L1
ZW2/SST
-X2
Sub-distribution unit internal installation
L1
BUP
HUP
BUP
FP1
N
GND
ZW1
TA
PE
Cut out auxiliary heating
5
MOT
A3
Accessories: Process water for changeover valve
L3
A1
ZW2/SST
A3
PE
N
2
F12
A1
PE
ZUP/ZIP
L1
Name
N
TBW
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
20.02.2007
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
08.12.2006Georg Bächmann
Georg Bächmann
SWC 60-170 terminal diagram
831120a
1/1
Ers. für
Anlage
Ort
Ers. durch
Name
Datum
Urspr.
Blatt-Nr.
Bl von AnzNorm
Zustand
Bearb.
Gepr.
Änderung Datum
Terminal diagramSWC 60H(/K) – SWC 170H(/K)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec SWC 140H and is the answer not in the manual?

Alpha-InnoTec SWC 140H Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelSWC 140H
CategoryHeat Pump
LanguageEnglish

Related product manuals