Chapter 2 Installation and Wiring
http://www.acdrive-china.com
19
Category Terminal
Name Functions Specifications
485+ RS485+
Communi
cation
485-
RS485
communic
ation
interface
RS485-
Standard RS-485
communication
interface
Not isolate with
GND
Please use
twisted-pair or
shielded cable
X1
Multi-
function
input
terminal 1
X2
Multi-
function
input
terminal 2
X3
Multi-
function
input
terminal 3
Be able to be defined
as multi- function
on-off input terminal.
See section 5.4 ,
Chapter 5 for the
function of input
terminals
(The common
terminal is PLC)
Optical-isolator
input
Input resistance:
R=3.9 k
Maximum input
frequency: 400 Hz
Input voltage range:
030V
X4
Multi-
function
input
terminal 4
Mult-func
tion input
terminal
X5 Multi-
function
input
terminal 5
In S2R4GB
3004GB, terminals
X4 and X5 can be
used as common
multi-function
terminals, they can
also be used as high
frequency pulse input.
In 35R5GB/37R5
PB3500G, they
only be used as
common multi-
function terminals
See section 5.4,
Chapter 5 for details.
In S2R4GB
3004GB
Maximum input
frequency: 50 Hz
Input voltage range:
030V
In 35R5GB/37R5PB
3500G:
Optical-isolator
input
Input resistance:
R=3.9 k
Maximum input
frequency: 400 Hz
Input voltage range:
COM
+24
X1
PLC
+
5V
24
R