INSTALLATION
Converge® Operator’s Manual MN-47239 Rev 3 5/23
32
How to Install the Oven (60 Hz Cord and Plug Models)
Before you begin Make sure you have:
An appropriate lifting device, and enough personnel, to safely move and position
the weight of the oven.
CMC-H2H: 304 lb (138 kg)
CMC-H3H: 394 lb (179 kg)
Requirements The oven must be installed on a level surface.
The oven must not be installed in any area where it may be affected by steam,
grease, dripping water, high temperature, or any other severely adverse
conditions.
The oven is not intended for built-in installation.
Voltages
Continued on next page
V Ph Hz A Breaker* kW
Plug
Configuration**
CMC-H2H 208
240
208
240
1
1
3
3
60
60
60
60
32
37
19
22
50
50
30
30
6.7
8.9
6.7
8.9
NEMA 6-50P
NEMA 6-50P
NEMA 15-30
NEMA 15-30
CMC-H3H 208
240
3
3
60
60
28
32
50
50
10.1
13.4
*Electrical connections must meet all applicable federal, state, and local codes.