INSTALLATION
Converge® Operator’s Manual MN-47239 Rev 3 5/23
35
How to Install the Oven
(50 Hz Models Without Cord or Plug)
Before you begin Make sure you have:
An appropriate lifting device, and enough personnel, to safely move and position
the weight of the oven.
CMC-H2H: 304 lb (138 kg)
CMC-H3H: 394 lb (179 kg)
Requirements The oven must be installed on a level surface.
The oven must not be installed in any area where it may be affected by steam,
g
rease, dripping water, high temperature, or any other severely
adverse
con
ditions.
The oven is not intended for built-in installation.
For 3-phase applications, an RCD Type B protection device must be installed. The
de
vice must accommodate a leakage current that may exceed 10 mA.
If a power cord is used for the connection of the product, an oil resistant cord like
H05RN or H07RN or equivalent must be used.
Voltages
Continued on next page
V Ph Hz A Breaker* kW
CMC-H2H 380
415
3
3
50
50
11
12
30
30
7.5
8.9
CMC-H3H 380
415
3
3
50
50
17
19
50
50
11.3
13.4
*Electrical connections must meet all applicable federal, state, and local codes.