46
Machine will not work
Inadequate suction force
Insufficient cleaning agent
supply
Suction nozzle making
stripes
> Machine not connected to
power supply.
> Internal fuse or FI protection
switch has activated.
> Power supply interrupted.
> Brush motor protection
switch has activated.
> SSB 430: Discharge signal
transmitter has activated.
> Suction hose and suction
nozzle is blocked with dirt
residue or hose is not
securely inserted into
suction nozzle.
> Filter in dirty water tank is
blocked.
> Tank lid not closed or lid
seals defective.
> Dirty water drain hose not
closed.
> Wrong suction nozzle angle.
> Cleaning agent residue in
piping system.
> Fresh water filter blocked.
> Water metering lever (pos. 0)
closed.
> Fresh water supply hoses
kinked.
> Worn suction lips.
> Dirt residue under suction
lips.
Plug machine into power
supply.
Check internal fuse and FI
protection switch.
Have supply checked by
authorised specialist.
Allow motor to cool, press
motor protection switch
pushbutton, put less fresh
water into the tank.
Charge battery.
Attach suction hose, remove
blockage.
Clean filter.
Close tank lid or replace
seals.
Close fastener.
Adjust suction nozzle angle.
(see chapter 3.3)
Flush fresh water tank and
piping.
Clean filter.
Move lever to pos. 1 to 4.
Inspect hoses.
Replace suction lips.
Clean suction lips.
Fault Cause Remedy
8 Troubleshooting