CHAPTER 3: OPERATING INSTRUCTIONS
DUAL PULSE 125
STORED ENERGY RESISTANCE WELDING POWER SUPPLY
3-6 990-270
a) Select PROGRAM].
b) Use SCHEDULE  to select SCHEDULE 0 if it is not already selected.
c) Press SAVE] and continue to hold it down for at least 1 second.
d) The SCHEDULE NUMBER will go blank.
e) Continue to press SAVE] and use SCHEDULE  to select another Schedule Number.
f) Release SAVE when the desired Schedule number is displayed.
g) The information from Schedule 0 has now been copied to the new Schedule number. BOTH
Schedules have the information saved in permanent memory.
Programming Squeeze Time
Users of Air Operated Weld Heads which do not have force-firing switches may use the Squeeze Time
feature. Squeeze Time begins when the 125DP recognizes an Air Head Connection and a Footswitch
closure (the first Level of a 1-Level Footswitch or the second Level of a 2-Level Footswitch). See
Chapter 2, Installing Air Actuated Weld Heads. After the Squeeze Time has elapsed the 125DP will
fire. It is not necessary to make a Firing Switch connection when using Squeeze Time.
Use the following procedure to program Squeeze Time:
a Press 1ST PULSE PROGRAM. The 125DP must be in the PROGRAM state to program Squeeze
Time. Any Schedule number can be displayed. Squeeze Time is a system parameter and will
be used by all weld schedules.
b Press 1ST PULSE PROGRAM again and hold. The ENERGY DISPLAY will display SQUEEZE
TIME in seconds. The PROGRAM indicators will go out while Squeeze Time is displayed.
c Press ENERGY  while holding 1ST PULSE PROGRAM to change Squeeze Time. Squeeze
Time can be set from 0.1 to 9.9 seconds. To disable set at 0.0.
d Release 1ST PULSE PROGRAM to SAVE Squeeze Time in permanent memory. Press RUN to
return to RUN state.