ACN-ML/ACN-MLP
Rev. 5.10
©2017, Ambient Recording GmbH
34
Bat
Li
Alk
NiMH
Not available on ACN-ML MasterLockit
This menu lets you tweak the battery telemetry read out to the cell type in use. Pick from Lithium,
Alkaline primary cells, and NiMH rechargeables. Readout follows typical discharge curve and accuracy
may vary over different manufacturers and battery types, so take with grain of salt.
IR
Off
On
Enables the infrared port above the OLED. Only useful in combination with ACC501 controller.
However, leaving the IR port open increases interference sensitivity and compromise reliability of the
unit in normal operation, so it is off by default and can only be enabled through “Extended” mode.
Reset
Factory Defaults: Yes
No*
Resets the devices to factory defaults as marked bold in this description
Info
DEV info
Debug1
Debug2
Screen test
First screen will show critical device information for serial number, firmware and FPGA software
revision, and MAC address, followed by 3 debug screens for developer use only.
9. LED Blink Codes
Code Legend
flash (generator sync)
●●
double flash (low batt warning every 2 seconds)
double blink (active ACN transmission)
-
blink (generator free lock)
--
long blink (ACN reception)
Red: Generator Not Set, no ext TC present
Green: Generator Set, running ext/ACN TC detected
Orange / Red & green simultaneously: standing ext/ACN TC detected