ThePoint Series
32
ATEX
Integral
II 2G Ex db ia IIC T5 Gb
II 2D Ex tb ia IIIC T95 oC Db
-30'C < To < 70oC
Remote
II 2 (1)G Ex db [ ia Ga] IIC T5 Gb
II 2 (1)D Ex tb [ ia Ga] IIIC T95 oC Db
-30'C < To < 70oC
FM 16ATEX0024X
IECEx
Integral
Ex db ia II C T5 Gb
Ex tb ia IIIC T90oC Db
-30'C < To < 70oC
Remote
Ex db [ia Ga] IIC T5 Gb
Ex tb [ia Ga] IIIC T95oC Db
IECEx FMG 10.0017X
4.1 Approvals Available
Remote:
Explosion-proof for Class I, Division 1, Groups A, B, C, and D;
Dust-Ignition proof for Class II, III, Division 1, Groups E, F, and
G; Non-incendiary for Class I, Division 2, Groups A, B, C, & D;
Suitable for Class II, III, Division 2, Groups F & G hazardous
outdoor Type 4, 4X, IP66 (classied) locations with Intrinsically
Safe connections to Class I, II, III, Division 1, Groups A, B, C,
D, E, F, and G hazardous (classied) locations in accordance
with Control Drawing 420-0004-181-CD.
Integral:
[Same, but Group A does not apply]
2460